Roof Lantern Installation

How Do You Choose Glazing for a Roof Lantern?


Choose roof lantern glazing in this order: safety build-up first (toughened outer pane, laminated inner pane, which is not optional on overhead glazing), then U-value, then solar control. For a south or west facing lantern in Suffolk, specify a solar control coated double unit with a g-value between 0.28 and 0.38 and a whole-unit U-value around 1.2 to 1.4 W/m²K. Add self-cleaning if you cannot reach it, and acoustic laminate only if you are under a flight path or a main road.

That covers the majority of kitchen extensions. The rest of this page explains why each decision sits where it does in that order, because the sequence is what stops people paying for the wrong upgrade.

Cut section of a roof lantern sealed unit showing the toughened outer pane, argon cavity, warm-edge spacer bar and laminated inner pane, photographed under flat diffuse daylight
Toughened outer, argon cavity with a warm-edge spacer, laminated inner. The standard overhead build-up.

1. The safety build-up, which is not a choice

Overhead glazing behaves differently from a vertical window because anything that fails lands in the room. The outer pane is toughened, so that if it breaks it goes to blunt granules rather than shards. The inner pane is laminated, meaning two sheets of glass bonded to an interlayer, so that if it breaks the fragments stay stuck to the interlayer and the pane holds in its frame rather than dropping onto whatever is underneath.

Some budget lantern systems are sold toughened-toughened. Do not accept it. The interlayer in the inner pane is the entire safety case for glass over a kitchen island, and the cost difference is small enough that any supplier avoiding it is telling you something about the rest of the specification.

2. U-value: how much heat leaves

The U-value measures heat loss, and lower is better. Under current Part L for England, a replacement rooflight in an existing dwelling must achieve a whole-unit U-value of 2.2 W/m²K or better. That is a legal floor rather than a target, and any decent modern lantern beats it comfortably.

What gets you there is three things working together: a low-emissivity soft coat on one cavity face, argon fill rather than air, and a warm-edge spacer bar instead of the old aluminium one. Aluminium spacers conduct heat straight round the edge of the unit and produce a cold line where condensation forms first. A warm-edge spacer is the cheapest meaningful upgrade on the whole specification.

Triple glazing takes a good aluminium lantern from roughly 1.3 down to roughly 0.9 to 1.1 W/m²K. It also adds around 40 per cent to the glass weight, which feeds back into the structural framing and sometimes into craneage. For most Suffolk extensions that trade is not worth making. Triple earns its place on very large lanterns, on low-energy builds, and on genuinely north-facing rooms where heat loss dominates and there is no solar gain to control.

3. Solar control: how much heat arrives

The g-value is the fraction of solar heat passing through the glass. A g-value of 0.65 lets 65 per cent through, which is what standard clear double glazing does. Over a 3.0 x 2.0m south-facing lantern above a room with a flat plastered ceiling, that is a serious quantity of heat arriving somewhere it cannot escape from.

A solar control coated unit brings the g-value to between 0.28 and 0.38 while keeping light transmission above 60 per cent, so the room still reads bright rather than tinted. Blue-green solar glass belongs to the 1990s; modern coatings are close to neutral. This is the single upgrade we recommend most often, and on a south or west facing lantern we treat it as default rather than optional.

Glazing recommendation by orientation
Lantern faces Recommended specification Why
South or south-west Double, solar control, g-value 0.28 to 0.34, plus a ridge opening vent Peak summer gain and a flat ceiling with nowhere for hot air to go
West Double, solar control, g-value 0.30 to 0.38 Late afternoon gain into evening living space
East Double, solar control or clear depending on shading Morning gain dissipates through the day
North, or heavily shaded Double or triple, clear, prioritise U-value and light transmission Little gain to control; heat loss and daylight matter more

4. Self-cleaning, tints and acoustic laminate

Self-cleaning is a hydrophilic outer coating that breaks down organic film in daylight and makes rain sheet rather than bead. On a lantern pitched at 20 to 25 degrees it works well, and it is worth having simply because you will not be up there with a squeegee. It does not eliminate cleaning, and it does very little against the salt film that builds within a couple of miles of the coast, which needs a fresh water rinse once or twice a year regardless.

Tinted and body-coloured glass is largely obsolete for solar control now that coatings do the job without the visual penalty. Where people still want it is privacy from an overlooking upper storey, and a fritted or obscure inner laminate handles that better than a tint.

Acoustic laminate uses a thicker or specially formulated interlayer to damp sound. It is a genuine upgrade under the Felixstowe port approach or beside a busy road, and pointless everywhere else. Rain noise on glass is a different problem and acoustic laminate helps with it only slightly; pitch does more, which is one of the quiet advantages a lantern has over a flat rooflight.

Ask for the whole-unit figure, not the centre pane. Centre-pane U-values look better because they exclude the frame and the spacer. Whole-unit values are what Building Control assesses and what lets you compare two quotes honestly. We state the whole-unit figure on every quote.

A roof lantern glazing bar and sealed unit edge seen against a uniformly grey overcast sky, showing the near-neutral tone of a modern solar control coating
Modern solar control coatings read close to neutral rather than tinted.

Related questions

Our roof lantern overheating page goes further into solar gain, and misted and blown glazing covers what happens when sealed units reach end of life. Both sit under roof lantern installation.

Get the specification in writing

We put the whole-unit U-value, the g-value and the light transmission on every quote, so you can compare it properly against anything else you have been sent. Request a fixed quote and we will confirm the glazing at survey once we know the orientation and the shading.

Thinking about this job? We survey across Ipswich, Suffolk and north Essex and give you a fixed price before any work starts, with a 10-year workmanship guarantee.

Get a fixed quote

Get a fixed quote

Tell us about the roof. We will tell you the price.

A survey costs you nothing and there is no obligation attached to it. We look at the roof build-up, the exposure and the opening, and give you one fixed figure, not an estimate that moves once work starts.

If your rooflight is leaking now, say so and we will prioritise the survey.

  • Fixed price, confirmed in writing
  • 10-year workmanship guarantee
  • Installed to current Building Regulations
  • Your roof is never left open overnight
Call Get a fixed quote